How Far Can I Run A 4/0 200 Amp Service Wire Underground
When installing a 200 amp electrical service, you need to be certain y'all use the right judge wire. You'll need a permit to practise the professional installation. Many areas still permit homeowners to obtain their permits. You'll need to check with your local building department to know if you can go the permit or if you'll need the assist of an electrician.
Installation of 200 amp electrical service needs a #two/0 AWG copper wire or #4/0 AWG for aluminum or copper-clad wire inside a minimum of 1.v inches, schedule 40 or fourscore PVC conduit for underground service. All the same, 2 or 2.v inches is recommended if running iii wires in the same conduit.
Wiring 200 amp service requires an electrical let and professional installation by a qualified electrician in accordance with local electric codes.
Power is received from the utility service lines and flows through the outside electrical meter base and into the main electrical panel in an attached garage, basement, or interior room.
Wire Sizes for 200 Amp Service
AWG, American Wire Estimate, is the Us standard for sizing electrical wiring.
Wiring a 200 amp feeder requires either #2/0 copper wiring or #iv/0 aluminum or copper-clad wiring. Which wire is used is determined by the voltage drop and length of the wiring.
The following table reflects wiring size, length, and voltage driblet:
Service or Feeder Rating | Copper Wire | Aluminum or Copper-Clad Aluminum Wire | Minimum Conduit Size |
---|---|---|---|
100 Amps | #4 AWG | #2 AWG | ane.25 inch |
110 Amps | #3 AWG | #1 AWG | one.25 inch |
125 Amps | #2 AWG | #1/0 AWG | one.25 inch |
150 Amps | #1 AWG | #ii/0 AWG | one.25 inch |
175 Amps | #one/0 AWG | #iii/0 AWG | 1.v inch |
200 Amps | #two/0 AWG | #4/0 AWG | 1.5 inch |
225 Amps | #3/0 AWG | 250 kcmil | 1.5 inch |
250 Amps | #4/0 AWG | 300 kcmil | 2 inch |
300 Amps | 250 kcmil | 350 kcmil | 2.5 inch |
350 Amps | 350 kcmil | 500 kcmil | three inch |
400 Amps | 400 kcmil | 600 kcmil | three inch |
Many electrical contractors opt to apply #4/0 aluminum or copper-clad wire.
For copper conductors, you'll need a #2/0 AWG copper wire normally used for electrical wiring because it is more rut resistant than aluminum. Copper won't rust and is resistant to oxidation.
For aluminum or copper-clad aluminum wiring, you'll demand #4/0 AWG aluminum wiring. Aluminum wiring requires a larger bore wire because it has a lower conductivity than copper. Aluminum wiring requires an antioxidant coating at the connection terminals to resist corrosion. Copper-clad aluminum doesn't require an antioxidant coating at the connection terminals.
Aluminum wirings appeal widespread because it costs less, is lightweight, and is more flexible than copper, even though copper is considered a ameliorate conductor.
Why Copper Wiring is Preferred over Aluminum
Electricians and homeowners alike prefer copper wiring, peculiarly for co-operative circuits. Copper wiring has many benefits, including:
- Conductivity: Copper wire is a highly conductive metal, 2d just to silver. Copper tin can handle a college electrical load, so you can use a smaller gauge wire. In fact, copper wire is well-nigh half the diameter of aluminum wire for the same conductivity.
- Heat Resistant: Copper wire conductive properties make the wire more rut resistant than aluminum wire. Copper wire does non expand and contract like aluminum which means the wire connections remain tight on lugs.
- Corrosion Resistant: Copper is resistant to corrosion. Patina is a greenish-tarnish that changes the outer color of copper. Patina forms by oxidation, however, exercise not touch the conductivity.
- Malleability: Because copper is highly conductive, the wire strands are thinner, making the wire more than malleable without the risk of breaking.
- Distance: Copper conductors tin can exist used over longer distances due to its highly conductive properties and estrus resistance.
Pros of Aluminum or Copper-Clad Aluminum Wire
We just discussed why copper is preferred; however, copper-clad and aluminum wire sizes are more popular on service entry wire for several reasons, including:
- Budget-Friendly: Aluminum wire is preferred due to its lower cost. Aluminum conductors are cheaper to produce compared to copper conductors. Aluminum copper-clad is better but does cost more than than aluminum wiring. Aluminum costs much less than copper-clad and copper wires.
- Faster Installation: Aluminum is lighter than copper and very malleable for its larger wire gauge. Electricians observe is piece of cake to work because is lightweight and feeds well through the electrical conduit which makes for faster installation and lowers fabric and labor costs.
Aluminum wiring expands and contracts with heat which causes the wire connection to loosen over time, raising the risk of an electrical burn down. Aluminum service wiring is a grouping of smaller solid aluminum strands rather than ane solid wire, making the aluminum wire safe to utilize in residential homes.
The Length Your Service Wire Runs Matters
When calculating wire size, you lot need to know how far the service entrance wires will run from the electrical meter base to the electrical panel. The maximum voltage drop (nosotros will discuss shortly) allowed is iii%. The distance your service entry wire needs to travel volition determine whether you utilise aluminum or copper wire and gauge necessary.
Service Wire Size | Maximum Distance |
---|---|
Copper #2/0 Wire | 50 feet |
Copper #three/0 Wire | 100 feet |
Copper #iv/0 Wire | 150 feet |
Aluminum #4/0 Wire | fifty feet |
Aluminum 300 kcmil | 100 feet |
You tin can use aluminum and copper for a 200 amp service entry wire. However, the aluminum gauge volition be college due to its reduced conductivity and heat resistance properties. You tin use copper wire over a longer distance.
What is Voltage Drop?
How Many Wires You Need for 200 amp Service
The blazon of wire you need will vary depending on your electrical arrangement. The run from the meter base to the main disconnect box or principal panel is three-wire, consisting of ii hot wires and 1 neutral wire. The neural and basis bars have electrical bonding connecting the confined.
The feeder run from the primary electrical panel to the interior distribution panel (subpanel) is 4-wire, consisting of two hot wires, 1 neutral wire, and one ground wire. You don't bail the neutral and ground bars inside subpanels.
What Size Conduit You Demand for 200 Amp Service
An electrical panel has knockouts for connecting electric feeder conduit. You can utilize either a 2-inch or ii.v-inch conduit based on the fill space you intend to occupy inside the conduit. If 3 or more wires are within the conduit, the maximum fill space of 40%.
In Chapter ix, Table 5A of the 2017 NEC, a #four/0 Aluminum stranded conductor takes upwardly 176.3mm2 of fill infinite. If you lot multiply 176.3mm2 by four gives yous a total of 705.2mmtwo of fill space used past the entire feeder.
According to Affiliate 9, Table 4 of the 2017 NEC, a 2″, Schedule eighty PVC conduit has 742mm2 usable fill.
Then, a 2″ conduit will suffice, or you lot can upsize to 2.5″ if you lot wish for ease of pulling. Continue in mind that the area of the wires must exist less than xl% of the internal space of the piping when 3 or more than wires are present.
What Size Ground Wire for 200 Amp Service
The NEC is the electrical code used in the United states of america. The minimum size for a grounding wire for 200 amp is #4 AWG copper or #2 AWG aluminum, according to Commodity 250 of the 2020 NEC.
The size of the principal usher may need to increase for a variety of reasons, including the length of the run, bachelor fault current, or any number of reasons. The NEC is a safety guide. Local municipalities set and adopt code guidelines. Phone call a local electrician or your urban center for specific guidelines.
GROUNDING ELECTRODE Conductor SIZING (Table 250.66)
Size of Main Panel | Copper Conductors | Aluminum or Copper-Clad Aluminum |
---|---|---|
125 Amps | #viii AWG | #6 AWG |
150 Amps | #six AWG | #4 AWG |
200 Amps | #four AWG | #2 AWG |
What Size Ground Rod for 200 Amp Service
A footing rod needs to be at least 5/8″ (0.625) in diameter and at least eight to 10 anxiety long with a clamp and the advisable ground wire. The basis rod needs to be driven 8 anxiety deep into the ground and cut back shut to the ground. The wire and clamp are secured tightly to the top of the ground rod.
Where there is a lot of electricity in the ground, a thicker #3 size wire may be required. Two footing rods are necessary for regions where soil electrical resistance is high considering of new code requirements.
Use the correct type of grounding rod. Pipe or rebar can also be used for grounding. The grounding rod must be galvanized steel and should be at least eight feet long.
How Many Ground Rods for 200 Amp Service
A footing rod that does not meet the NEC'south 25 OHMS or less requirement necessitates using a second ground rod, with the ground rods beingness at to the lowest degree 6′ apart.
You install a footing rod for a system, and the first basis rod has a resistance of 25 ohms or more. According to the NEC, you lot must install a 2nd grounding rod. On the other hand, many contractors practise non take ground resistance into account. They anticipate driving two ground rods to satisfy 250.56'southward standards regardless of actual ground resistance. As a result, two footing rod connections are typical but aren't always necessary.
The NEC article 250.53(B) requires you to space grounding rods at to the lowest degree vi feet apart connecting by a grounding wire. However, this spacing is a minimum. When using the typical 8-human foot or 10-foot ground rod, you get the all-time results past spacing them at least 16 or 20 feet autonomously, much further than the minimum half-dozen-pes spacing.
Check Local Electric Codes & Let Requirements
Electrical codes are set past the National Electrical Lawmaking (NEC) but can vary by location. Using a qualified electrician ensures your 200 amp electrical service meets local codes and permit requirements.
The 200 amp size wire referred to in this article is from the NEC code and may vary from your local edifice code. Your local code volition adopt or alter the NEC codes to fit their requirements.
Before the utility service can connect power to the house, y'all'll need a Document of Occupancy (CO). The permit allows for a terminal inspection to connect the electric service. The CO is issued after the electrical work has passed the building inspection.
200 Amp Electric Service Installation Costs
It's well-nigh impossible to accurately price the toll of installing a 200 amp entry service in a house. We need to consider numerous factors, like location, the amount of work required, and textile costs in your area. Installing a 200 amp electrical service typically includes installing a 200 amp service wire, conduit, meter base, and a 200 amp electric panel.
Based on HomeAdvisor.com, the national boilerplate price of a complete 200 amp electric installation costs $1,900 to $7,250, with average costs of $iv,650, includes the following:
- 200 Amp Service Panel: Boilerplate cost ranges from $750 to $2000, with a median toll of $1375.
- 200 Amp Meter Base: Average cost ranges from $150 to $400, with a median cost of $275.
- 200 Amp Service Wire: Average cost ranges from $1000 to $5,000, with a median cost of $3,000.
According to MidPenn Electric, a leading electrical contractor in Pennsylvania, "a new 200 amp service can toll anywhere from $4,200 to $five,000". Therefore, the HomeAdvisor price averages seem to be reasonably accurate.
Conclusion
Installing 200 amp wire is non a DIY project for homeowners. Wiring a 200 amp panel is a big projection that requires the services of a qualified and certified electrician. You may require a let to install a 200 amp service. The electric service will demand to be disconnected entirely in existing homes to install the 200 amp service.
Also, see our guide, Wire Size for 100 Amp Electrical Service.